|
||||||||
![]() |
||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]()
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
The vector sequence has been compiled using the information from sequence databases, published literature, and other sources, together with partial sequences obtained by Evrogen. This vector has not been completely sequenced. |
|||||||||||||||||||||||||||||||||||||||||||||||||
![]() Download
|
| ||||||||||||||||||||||||||||||||||||||||||||||||
Location of features
PCMV IE: 1-589
Enhancer region: 59-465
TATA box: 554-560
Transcription start point: 583
Connexin 26: 683-1360
TagFP635: 1382-2095
SV40 early mRNA polyadenylation signal
Polyadenylation signals: 2248-2253 & 2277-2282
mRNA 3' ends: 2286 & 2298
f1 single-strand DNA origin: 2345-2800
Bacterial promoter for expression of Kanr gene
-35 region: 2862-2867
-10 region: 2885-2890
Transcription start point: 2897
SV40 origin of replication: 3141-3276
SV40 early promoter
Enhancer (72-bp tandem repeats): 2974-3045 & 3046-3117
21-bp repeats: 3121-3141, 3142-3162 & 3164-3184
Early promoter element: 3197-3203
Major transcription start points: 3193, 3231, 3237 & 3242
Kanamycin/neomycin resistance gene
Neomycin phosphotransferase coding sequences:
Start codon (ATG): 3325-3327
Stop codon: 4117-4119
G->A mutation to remove Pst I site: 3507
C->A (Arg to Ser) mutation to remove BssH II site: 3853
Herpes simplex virus (HSV) thymidine kinase (TK) polyadenylation signal
Polyadenylation signals: 4355-4360 & 4368-4373
pUC plasmid replication origin: 4704-5347
Evrogen FP-related products are intended for research use only and covered by Evrogen Patents and/or Patent applications pending. By use of these products, you accept the terms and conditions of the applicable Limited Use Label License.
The CMV promoter is covered under U.S. Patents 5,168,062 and 5,385,839, and its use is permitted for research purposes only. Any other use of the CMV promoter requires a license from the University of Iowa Research Foundation, 214 Technology Innovation Center, Iowa City, IA 52242.
To the best of our knowledge, these products do not require a Material Safety Data Sheet. However, all the properties of these products (and, if applicable, each of their components) have not been thoroughly investigated. Therefore, we recommend that you use gloves and eye protection, and wear a laboratory coat when working with these products.
|
Copyright 2002-2008 Evrogen. All rights reserved. Evrogen JSC, 16/10 Miklukho-Maklaya str., Moscow, Russia, +7(495)4298020, e-mail:evrogen@evrogen.com |